Sign In | Join Free | My himfr.com
Home > Magnetic Particle Testing Equipment >

110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections

    Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
     
    Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers
    • Buy cheap 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections from wholesalers

    110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections

    Ask Lasest Price
    Brand Name : HUATEC
    Model Number : HCDX-230AC
    Certification : CE ISO
    Payment Terms : T/T,paypal, western union
    Supply Ability : 500pcs per month
    Delivery Time : 3 working days
    • Product Details
    • Company Profile

    110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections

    110V Electromagnetic Yoke Magnetic Particle Testing Equipment Handy Magna


    The portable series magnet yoke detector is a light and small magnetic particle flow detector device which magnetizing the magnetic work-piece by magnet yoke. It is suitable for flaw detect in varies parts, such as in oil-field, ship-building, diesel engine parts, miner, machinery, standard parts, oil pump and nozzle, airplane-manufacture, mobile parts, bridge-build, chemical industry, boiler, pressure vessels, railway industry products or the parts which have surface defect resulted in forging, quenching, welding and fatigue, such as connecting rod, crankshaft, bearing, high strength bolts, springs, forging parts, pipes, valves, blades, gears, rolling parts, anchor chain and the parts with complicated geometric figure.

    There is AC, DC, AC-DC type of the portable series magnet yoke detectors. The power source for DC type detector is chargeable cell and can continuously work for 6 hours with one time charged. It is suitable for field operation of container, bridge and pipes without power supplier or high voltage is unable to connected. The AC type detector is charged with 220V and 110V power supplier. It is widely used since easy to operated, simple in structure, lightly in weight and easy to carry.


    Technical Parameters

    Model


    Categories

    HCDX-230

    AC-DC

    HCDX-230

    DC

    HCDX-230

    AC

    HCDX-230E

    AC-DC

    Power supply220V 50Hz-12V12/V110V/220V 50Hz220V 50Hz
    Charging power~220V 50HZ~220V 50HZ//
    BatteryMF12-10BMF12-10B//
    Working current

    AC 3A

    DC 3A

    3A3A3A(AC-DC Switching Converters)
    Charging duration8~15h8~15h//
    Battery durationMore than 6hMore than 6h//
    Aperture time3 ~ 5 seconds on / 3 to 5 seconds off
    Magnetizing length50-200mm50-200mm50-200mm50-240mm

    Lift

    force

    AC≥4.8㎏/≥4.8㎏≥5.5㎏
    DC≥18.5㎏≥18.5㎏/≥25㎏
    WeightProbe3.2㎏3.2㎏3.2㎏3.5㎏

    Battery

    box

    2.9㎏2.9㎏//

    Figure

    size

    Probe208×48×148208×48×148208×48×148210×60×260

    Battery

    box

    165×142×77165×142×77//

    Principles and Applications

    3.1 Charging(with charger or accumulator-HCDX-230 AC-DC,HCDX-230 DC):

    Connect charger to power supply or connect charger to accumulator box with cable. 3 tubes will indicate charged state while charging. The red indicates quickly charged, the yellow indicates slowly charged (may continuously charge for 4 hours) and the green indicates 14 volts already charged. If the tube indicates yellow at start, it can be continuously charged but totally not more than 15 hours.


    3.2 Accumulator

    Accumulator is the power supply of probe. After turn on the switch, the monitoring circle is working. When voltage is over 10.4V, the tube turns green and means power normally supplied. When voltage is reached to 10.4V, the tube turns red flash and means voltage is reached to 10.4V, the tube turns red flash and means voltage is not enough. When voltage is at 10.2V, means self-protection is started and power supply to the probe soon stopped. When the tube continuously red flash, means voltage is not enough. Therefore, the working switch should be turn off and the accumulator should be power recharged.


    3.3Fault detection

    A:When detect it with DC (suitable for HCDX-230 DC,HCDX-230 AC-DC):

    1. Connect probe with cell, when the working switch at position “on” means power is supplied to the probe.
    2. Put the probe on work-piece to be detected and keep it well touched.
    3. Push down the button of probe and spray magnetic powder or magnetic suspension liquid to the area to be detected at the same time and keep it for 2~3seconds.
    4. Release the button of probe and move the probe away and observe the working result carefully.
    5. Move the probe to another area to be detected and repeat the working steps according to 3)and 4) above.

    B:When detect it with AC(suitable for HCDX-230,HCDX-230E AC-DC,HCDX-230 AC-DC)

    1. Put the plug into the socket which should be contacted the earth.
    2. Reference to the working steps 3)and 4) of the Dc when detected.
    3. The implementation of testing using the HCDX-230E, the exchange of the work piece when the selection switch for the exchange of inspection, when placed in the DC to DC testing. Non-magnetic state in the conversion pass selector switch.

    4. Maintenance

    1)The charging duration is not over 15 hours for each time when charging with charging device. Disconnect the battery cable form charging device or turn off the accumulator switch to proven the current flow reversed.

    2)It should be charged as quickly as possible when voltage of accumulator is not enough.

    3)It should be charged for every 2~3 months when the detector is not used for a long time , so as to guarantee serviceable life of the accumulator.

    4)While the probe is used, time of power supplied general 2~3 seconds for each time and maximum is not over 5 seconds. Time of interval is 3~5 seconds.

    5)The rust-proof agent should be added when magnetic suspension liquid used.

    6)Some oil lubricant should be added at moving joint before the probe used. The water, oil and magnetic particles on moving joint should be cleaned out and rust-proof oil should be smear after the probe used.

    7)The power supply should meet the requirements of indications and in good earth contacted when detected with AC.

    8)The switch should be released when moving the probe, so as not resulted of heat to the detector.

    9)Short break is necessary if the detector continuously worked or obviously heated.

    10)Working with the detector, it is not allowed under high temperature, high humidity or raining. The magnetic suspension liquid is not allowed sprayed on the switch, plug or sockets.


    Basic Configuration

    Type

    HCDX-230

    AC-DC

    HCDX-230

    DC

    HCDX-230

    HCDX-220E

    AC-DC

    Main detector,

    Probe&cable

    1 set1 set1 set1 set
    Charge& wire1 piece1 piece//
    Battery box1 box1 box//
    Flexible joint

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    Power wire1 piece1 piece//
    Cable1 piece1 piece1 piece1 piece
    Packing case1 piece1 piece1 piece1 piece
    Operation instructions1 piece1 piece1 piece1 piece
    Certifications1 piece1 piece1 piece1 piece

    Quality 110V Electromagnetic Yoke Magnetic Particle Testing Equipment 4 Sections for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: HUATEC GROUP CORPORATION
    *Subject:
    *Message:
    Characters Remaining: (0/3000)